XE910-2G

0 out of 5

• Power Socket (PWR, GND, RESET)

• D-Type 9-Pin RS232 Connector

• Mini USB Connector (ESD protection for USB 2.0)

• 2×4 GPIO Socket

– RS485 – Transceiver with AutoDirection Control

– 2 Output – 2 Input – 1 Analog Input

• Cellular Antenna Connector (SMA-F 50Ohm)

• On board Push-Push Sim Card Holder

• 2 operating status LED’s (Power / Status)

Açıklama

Interfaces Electrical & Sensitivity
Power Socket (PWR, GND, RESET) Supply voltage: 9–35VDC @ 1.2A min
D-Type 9-Pin RS232 Connector Battery: Li-Ion 3.7V 960mAh (Optional)
(RS-232 transceivers with integrated ESD protection) Output power
Mini USB Connector (ESD protection for USB 2.0 interfaces) Class 4 (2 W, 33 dBm) @ GSM 850/900
2×4 GPIO Socket Class 1 (1 W, 30 dBm) @ GSM 1800/1900
RS485 – Transceiver with AutoDirection Control Cellular Sensitivity
2 Output (Relay Driver Max 12V @ 150mA) 107 dBm @ GSM 850/900 MHz
2 Input (Optical isolator 9-24V DC) 107 dBm @ DCS1800/PCS1900 MHz
1 Analog Input (0-5V DC)
Cellular Antenna Connector (SMA-F 50Ohm) Software
On board Push-Push Sim Card Holder Python* versiyon: 2.7.2 application resources
2 operating status LED’s Python* script interpreter
Power / Status (module takes the application code
directly in the Python* language)
Cellular Features Memory: 2 MB of NV memory for the
4 Bands GSM | GPRS : user scripts and 2 MB RAM for the
850 / 900 / 1800 / 1900 MHz Python* engine usage
Quad Band GPRS class 10 AppZone application resources
SIM Access Profile Programming language: C
3GPP release 4 compliant IDE: Eclipse
Control via AT commands according to Dedicated File System: 5 MB
3GPP TS27.005, 27.007 and customized Separate App. RAM Space: 2 MB
Telit AT commands
Serial port multiplexer 3GPP TS27.010 Mechanical / Environmental
SIM application Tool Kits 3GPP TS 51.014 Dimensions 85 x 80 x 30 mm
Builtin UDP/TCP/FTP/SMTP stack Weight: 140 grams (with battery)
Voice and SMS Extended temperature range:
Standard and extended AT command set -40°C to +85°C (Operational)
Jammer rejection
Data
GPRS
GPRS class 10
Mobile station class B
Coding scheme 1 to 4
PBCCH support
GERAN Feature Package 1 support (NACC, Extended TBF)